Petrochemical Plant
A three-phase separator feeding a fractionation column, with the level and pressure trips that stop liquid reaching a gas compressor.
Startup. Levels established before heat is applied, compressor on recycle until suction is dry.
Deviation library
Components
Explore the equipment
Separate a multiphase hydrocarbon feed into gas, liquid and water, then fractionate the liquid — holding levels and pressures inside the envelope each downstream machine can tolerate.
Components
Feed lineLN-301
Brings multiphase feed into the train
Normally: Steady flow at design rate
Three-phase separatorSEP-301
Splits gas, hydrocarbon liquid and water
Normally: Interface and liquid level under control
Fractionation columnCOL-301
Separates the liquid into products by boiling point
Normally: Temperature profile stable across the trays
ReboilerREB-301
Supplies heat to the column bottoms
Normally: On duty, steam flow modulating
Overhead condenserCND-301
Condenses the overhead vapour
Normally: Cooling water flowing, outlet temperature steady
Compressor KO drumKOD-301
Catches liquid before the gas compressor
Normally: Empty, level transmitter live
Gas compressorCMP-301
Compresses separated gas for export
Normally: Running, suction free of liquid
Flare headerFLR-301
Takes relieved and blown-down hydrocarbon to the flare
Normally: Clear, purged
Operating states
Normal Operation
Separator on level control, column at steady profile, compressor exporting gas.
Startup
Levels established before heat is applied, compressor on recycle until suction is dry.
Shutdown
Feed isolated, inventory depressured to flare, column cooled under control.
Failure scenarios and safeguards
MORELevel
Feed and compressor trip before liquid reaches the compressor suction.
Causes
- Liquid outlet valve fails closed
- Slug arriving from the feed line
How it develops
- 01Liquid accumulates faster than the outlet can drain it.
- 02Level reaches the gas outlet and liquid begins to carry over.
- 03Knock-out drum fills and the compressor trips on high level.
Safeguards
High level tripLSHH-301
Trips the feed on high-high level in the separator
If it fails: Liquid continues to accumulate towards the gas outlet
KO drum level tripLSHH-302
Trips the compressor on liquid in the knock-out drum
If it fails: Liquid reaches a machine designed only for gas
Unmitigated: Liquid enters a gas compressor, which cannot compress it — mechanical damage and a potential loss of containment.
MOREPressure
The column relieves to flare and stays within its design pressure.
Causes
- Loss of cooling water to the overhead condenser
- Reboiler duty left on with the overheads blocked
How it develops
- 01Overhead vapour stops condensing.
- 02Pressure climbs through the column as vapour has nowhere to go.
- 03Relief lifts and the column vents to the flare header.
Safeguards
Column reliefPSV-301
Relieves the column to flare on overpressure
If it fails: The column is exposed above its design pressure
Unmitigated: The column is taken above design pressure with no relief path.